Reasons Why an IP Paging System is Important for Modern Services

Wiki Article

Network PA System for medium to massive tasks

Intro

The XC-9000 system is a completely digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP procedure, the system guarantees the reliable and appropriate transmission of all data packages. Not just can it use existing local area network, such as LANs or the Web, to transfer program signals, but also it can additionally be released on a devoted broadcasting network.

The server is extremely effective. Even when gotten in touch with a a great deal of terminals, it can concurrently deal with the very same task smoothly. A single-server system can sustain as much as 3000 terminals and permits web server cascading. There are no constraints on the concurrent broadcast networks, accomplishing real complete digital broadcasting .

System Qualities

Flexible PA System Style

The PA system design is basic, including service management software program, network microphones, network amplifiers, network audio speakers, and other devices.All equipment is linked via the TCP/IP intranet protocol, enabling versatile arrangement and simple management of the system, with complimentary control over broadcast material, network tools, and areas via the network.

Ip Paging MicrophoneIp Paging System
Comprehensive Sound Monitoring

The audio monitoring software consists of built-in functions for developing broadcast plans, versatile zoning, and pre-scheduled broadcasts.It supports 24-hour programs, allowing for changing settings during throughout the day

Versatile Audio Source Assistance

The system sustains different forms of audio resources for sending notices like live speech and BGM playback. Sound resources can originate from electronic music applications, CD/DVD gamers, microphones, etc. Furthermore, the system supplies varied features of supporting different broadcasting functions such as set up broadcasting, zoned broadcasting, and emergency situation broadcasting.

Emergency Alarm System Combination

The system has an emergency alarm function and can be incorporated right into an emergency alarm system. When the alarm system central system obtains the worrying signals, the cable television will transmit the signal to tools, which activates the XC-9000, sending signals to audio speakers

Individuals might pick to predetermined settings to turn on full-area or zoned alarm systems in emergencies. The alarm voices come in several types and could be modified accommodating demands. For instance, users can alter language setups, upload and edit their audio resources according to exact demands, such as intruding alarms, emergency alarm or air help alarm systems, etc



Fire Alarm System Integration

The system has a fire alarm system feature and can be incorporated into a smoke alarm system. When the alarm main system gets the disconcerting signals, the cable television will send the signal to devices, which triggers the XC-9000, sending signals to speakers

Customers could choose to pre-programmed settings to trigger full-area or zoned alarms in emergencies. The alarm system voices can be found in numerous forms and can be modified accommodating requirements. Customers can change language settings, upload and edit their audio sources according to specific requirements, such as intruding alarms, fire alarms or air aid alarms, etc.

Application Control for System Operations

The system allows mobile app login and usage, enabling users to launch broadcasts and other operations to authorized terminals via the web server software, ensuring a streamlined and practical experience.

Integrated SIP Compatibility

The system not just enables SIP phones to visit, but likewise can be connected to third-party SIP web server or IPPBX, which develops an entirely integrated and compatible communication system with seamless integration into existing systems.

Open SDK

When big job like smart park takes place, the system gives an open SDK integrated into third-party application systems - IP PA System

System Framework

Key Functions

Scheduled Playback

The system has the ability to instantly transmit according to the set up tasks as long as individuals submit the audio apply for each time duration of the day to the web server and produce a playback timetable.

Zone Broadcasting

The system can randomly separate a few network gadgets into different areas to play defined audio programs or send statements to any type of assigned location. The quantity of each gadget can be from another location changed.

Real-time Broadcasting

The system can record and broadcast radio programs or other external audio sources in real-time, and at the exact same time relayed them in sync.

Fire Alarm Combination

The system can be incorporated with the emergency alarm system for control. When a fire alarm signal is triggered, it immediately triggers the emergency broadcast function and supports surrounding flooring alarm systems. It also permits for hands-on emergency broadcasting by clicking a single switch.

SIP Phone Combination

The system can be incorporated with SIP web servers, enabling online speech of voice broadcasting by means of SIP phones to send out statements anytime and anywhere.

CCTV Assimilation

The digital tools such as IP POE Speakers adopts the global conventional ONVIF method, which allows their voices to be transmitted by means of VMS systems. The terminals can likewise be integrated with CCTV systems for integrated broadcast.

Main Products

Audio Monitoring Software Application XC-9000

B/S design, sustains cross-platform applications. Covers conventional broadcasting system works, enabling for partition administration. Unified administration of terminals within the system, watching job status, and set quantity adjustment, etc. Sustains structure multi-level web server styles, deploying administration according to user geographical areas. Offers SDK advancement bundles for second advancement and integration with various other system platforms.

Network Paging Console XC-9038N

Power: DC12V/1.5 A. Show: 4-inch touchscreen, resolution 480 * 480. Communication Protocols: TCP/IP, UDP, SIP. Signal-to-Noise Ratio: > 80dB. Frequency Reaction: 100Hz~ 16KHz. Running Temperature: 0~ 45 ℃. Dimensions: 144 * 144 * 34.1 mm.

Network Paging Console XC-9037N

Power Supply: DC12V/1.5 A. Show: 4-inch touchscreen, resolution 480 * 480. Communication Methods: TCP/IP, UDP, SIP. Signal-to-Noise Proportion: > 80dB. Regularity Reaction: 100Hz~ 16KHz. Operating Temperature: 0~ 45 ℃. Dimensions: 144 * 144 * 34.1 mm.

Network Horn Audio Speaker GEN-6391A03

Power Supply: DC24V/2.7 A or POE. Communication Method: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Ratio: > 80dB. Regularity Reaction: 100Hz~ 18KHz. Intercom: Sustained, click reference Built-in Microphone. Running Temperature: -20~ 50 ℃. Dimensions: 283.1 * 224.3 * 269mm.

Network Ceiling Speaker GEN-6211A03

Power Supply: DC 24V/1A or POE. Communication Methods: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Ratio: > 80dB. Frequency Reaction: 100Hz~ 18KHz. Operating Temperature level: -20 to 50 ° C. Capacities: φ213 x 165mm.

Network Wall Mount Audio Speaker GEN-6011A03

Power Supply: DC24V/1A or POE. Communication Procedure: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Ratio: > 80dB. Frequency Action: 100Hz~ 18KHz. Running Temperature level: -20~ 50 ℃. Dimensions: 193x151.5 x292mm.

Network Column Audio Speaker GEN-6191A03


Power Supply: DC24V/1A or POE. Communication Procedure: TCP/IP, UDP, SIP. Signal-to-Noise Ratio: > 90dB. Frequency Feedback: 45Hz~ 18KHz. Running Temperature level: -10~ 55 ℃. Dimensions: 296x140x130mm.

Network Sound Bridge GEN-3101A01

Power Supply: POE. Interaction Method: TCP/IP, UDP, SIP. Signal-to-Noise Proportion: > 85dB. Frequency Reaction: 50Hz~ 20KHz. Running Temperature level: -10~ 55 ℃. Dimensions: 126x66x27mm.

Network Digital Amplifier XC-9508P

Power Supply: AC100V~ 240V, 50/60Hz. Power: 130W, 260W, 360W, 500W. Interaction Method: TCP/IP, UDP, SIP. Signal-to-Noise Proportion: > 80dB. Regularity Response: 60Hz~ 18KHz. Running Temperature level: -10~ 50 ℃. Dimensions: 440x300x44mm.

Area Combining Digital Amplifier NBS-2301

Power Supply : AC 220V, 50Hz. Power : 130W , 260W , 360W , 550W , 700W. Interaction Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP. Signal-to-Noise Ratio :. Mic Input 01: ≥ 65dB,. Mic Input 02/03: ≥ 80dB,. Aux Input 01/02: ≥ 82dB. Frequency Response :. Mic Input 01: 80Hz~ 14kHz. Mic Input 02/03: 60Hz~ 16kHz. Aux Input 01/02: 60Hz~ 16kHz. Operating Temperature level :. 10 ℃~ +50 ℃ (14 ℉~ 122 ℉) Dimensions : 483x430x88mm.

IP Interface System NAC-5003

Power Supply: AC100V~ 240V, 50/60Hz. Communication investigate this site Method: TCP/IP, UDP. Interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system outputs. Operating Temperature: -10~ 50 ℃. Measurements: 483x259x44mm.

Option For School



Flexible Zoning Program:

The fully network terminals can realize adaptable zoning alternatives, permitting transmitting alerts to individual terminals or different areas ( devices).

Institution Bell System:

It supplies institution bell system at the beginning/ending of the class - IP Paging Microphone. Several circumstances can be created, consisting of different arranged program tasks according to summer/winter schedule

Fire Alarm Combination

It supports integration with emergency alarm systems, enabling fire alarm system signals to be integrated right into the PA system.

Classroom Sound Boosting

Terminals sustain day-to-day applications in classroom scenes. They can be connected to projectors or interactive white boards for audio amplification.

Spon CommunicationsSpon Communications

Smart Road Lamp/Security Pole

Assistance SIP Procedure:

Integrated SIP protocol for smooth assimilation with network communication systems.

VMS Platforms Integration:

Integrated ONVIF method for assimilation with VMS systems.

Third-Party Integration:

Constructed In HTTP API for integration with 3rd party systems.

Voice Alarm Activating:

Constructed in alarm system input user interface for activating voice alarms with cameras.

Service For Hotel

Zone Control by Floor:

The system supplies complete network setups, dividing areas depending on different floorings and control over each area individually.

Emergency Alarm Assimilation:

The system can be incorporated with smoke alarm system, making it possible for integration of fire alarm system signals right into the broadcasting system.

Scheduled Broadcasting:

It sustains programmable arranged broadcasting, enabling versatile setups according to different click here for more info needs.

Emergency situation Broadcasting:

It sustains emergency broadcasting for the entire location, allowing one-click emergency situation communication.

Remedy For Manufacturing facility

Zone Broadcasting:

It allows broadcasting to any kind of zone, ensuring no disturbance between various areas.

Alarm system Triggering:

Terminals have different kinds of interfaces, enabling to cause alarm systems when linked with cams.

All Network Devices:

Deployment of fully network gadgets dramatically decreases the problem of running such as examining devices on unsafe sites, and therefore securing people and residential property.

The implementation of all network tools greatly reduces the difficulty of operation and maintenance administration

Integrated SIP Phones:

The system can be incorporated with SIP phone and program notifications utilizing SIP phones any time and anywhere. Two-way audio talkback in between SIP phones and IP POE Audio speakers makes it simple for examining tools sitting in workplace or other work environments.

The XC-9000 system is a totally electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system ensures the right and effective transmission of all data packets. The system sustains numerous types of audio sources for sending out notices like online speech and BGM playback. In addition, the system gives varied functions of supporting various broadcasting features such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.

The system can be incorporated with the fire alarm system for control.

Report this wiki page